ESXi Boot Loop on Dell PowerEdge R720

We have faced quite a strange issue with one of our Dell PowerEdge servers on a remote site. When the branded image was deployed on the host, we kept getting bootloops. The system has just started unloading modules after they were seemingly loaded. After inspecting the vmkernel log at boot-time by pressing ALT-F11, I have noticed a few strange warnings:

2014-11-24T04:13:50.237Z cpu2:2631)WARNING: ScsiScan: 1485: Failed to add path vmhba1:C0:T0:L0 : Not found
2014-11-24T04:15:08.990Z cpu7:2792)WARNING: ScsiScan: 1485: Failed to add path vmhba1:C0:T0:L0 : Not found

I have poked around the settings in BIOS to find out what could have been causing the issue that were seemingly coming from the RAID controller itself. I have changed the SATA to report as RAID opposed to AHCI which was set previously, and the next boot was successful.

This didn’t have any effect on already present drives or data because the only device that used the on-board storage controller was the DVD-ROM.

Advertisements